1. Identification of the substance/mixture and of the company/undertaking

Product Name: Acrylic ester copolymer

Recommended use: Water-borne top-coat material for acrylic sports courts.

Restrictions on use: For industrial application only; not intended for direct consumer use.

Company: Guangzhou Lianyi Chemical Co., Ltd.

Address: Room 309, No. 27 Fuqian Road, Xintang Town, Zengcheng District, Guangzhou City, Guangdong Province, China

Telephone: (+86)20-82038946

Emergency Telephone: (+86)20-82038946 / (+86)13710203095

Email: 25529266@qq.com

2. Hazards identification

Hazard Classification: This product is NOT classified as a hazardous chemical under GHS criteria.

Routes of Entry:

- Inhalation: Mist droplets may be generated during application processes (e.g., spraying). Inhalation may irritate the respiratory tract.

- Skin Contact: May cause mild irritation. Some individuals may experience allergic reactions.

- Ingestion: May irritate the gastrointestinal tract if swallowed.

Health Hazards:

- Acute Toxicity: Generally low toxicity. However, significant inhalation or ingestion may cause discomfort, such as coughing, nausea, or vomiting.

- Chronic Effects: Prolonged or repeated exposure may cause irritation to the skin and respiratory tract, potentially leading to skin dryness or respiratory inflammation.

Signal Word: Not applicable

Hazard Statements: Not applicable

Precautionary Statements: Not applicable

3. Composition/information on ingredients

No.NameCAS No.PercentageHazardous Substance?
1.Acrylic Emulsion25085-34-140%No
2.Titanium Dioxide, Calcined Kaolin, etc.1317-80-228%No
3.Additives9006-65-92%No
4.WaterNone30%No

4. First-aid measures

Skin Contact: Immediately remove contaminated clothing. Wash skin thoroughly with plenty of water and soap for at least 15 minutes. Seek medical attention if irritation occurs.

Eye Contact: Immediately lift eyelids and rinse cautiously with copious amounts of flowing water or normal saline for at least 15 minutes. Seek immediate medical attention.

Inhalation: Move rapidly to fresh air. Keep airway clear. If breathing is difficult, give oxygen. If breathing has stopped, give artificial respiration immediately. Seek medical attention.

Ingestion: If swallowed, rinse mouth immediately. Do NOT induce vomiting unless directed by medical personnel. Seek medical attention.

5. Fire-fighting measures

Fire Hazard: Generally non-combustible. However, under extreme conditions (high temperature, open flame), some organic components may burn.

Hazardous Combustion Products: Combustion may produce carbon monoxide (CO), carbon dioxide (CO₂), nitrogen oxides (NOₓ- if nitrogen-containing components burn), etc.

Suitable Extinguishing Media: Water spray, dry chemical powder, carbon dioxide (CO₂) extinguishers.

Extinguishing Methods: Use cooling, isolation methods. Prevent spread of fire.

6. Accidental release measures

Emergency Procedures:

Evacuate personnel from the spill area immediately. Isolate hazard area and restrict access.

Eliminate ignition sources (if possible).

Small Spills: Absorb with inert material (e.g., sand, earth, vermiculite). Collect and transfer to approved waste disposal containers/facility.

Large Spills: Contain spill using dams or dikes. Transfer recovered material using pumps to tank trucks or specialized collectors for recovery or disposal at an approved waste facility. Prevent entry into sewers or waterways.

7. Handling and storage

Handling Precautions:

Personnel should wear appropriate protective equipment (work clothes, gloves, safety goggles, etc.).

Ensure adequate ventilation in the workplace. Avoid application in confined spaces.

Keep away from ignition sources, heat, and open flame. Use explosion-proof ventilation systems and equipment.

Storage Conditions:

Store in a cool, well-ventilated warehouse/store.

Keep away from ignition sources and heat.

Store separately from strong oxidizing agents, strong acids, and strong alkalis. Do not store together.

Storage area should be equipped with spill control equipment and suitable containment materials.

8. Exposure controls / personal protection

Occupational Exposure Limits: No specific occupational exposure limits established. (Fill in according to applicable national or industry standards if they exist).

Monitoring Methods: No specific monitoring required. (Fill in if required).

Engineering Controls: Ensure good natural ventilation. Use local exhaust ventilation equipment if necessary.

Respiratory Protection: Normally not required under conditions of good ventilation. In case of poor ventilation or high concentrations during application, use a self-contained filtering respirator (half mask).

Eye Protection: Wear chemical splash goggles to prevent contact.

Skin/Body Protection: Wear general work clothes.

Hand Protection: Wear chemical-resistant gloves, such as nitrile gloves.

Other Protective Measures: Prohibit eating, drinking, and smoking in the work area. Wash thoroughly and change clothes after handling. Maintain good personal hygiene practices.

9. Physical and chemical properties

Appearance: Homogeneous liquid, blue

pH: 8.0

Melting Point/Freezing Point: Not applicable

Flash Point: Not applicable

Flammability: Generally non-flammable

Solubility: Dispersible in water; some components soluble in organic solvents

Relative Density (Water=1): 1.08

Vapor Density (Air=1): >1 (Air=1)

10. Stability and reactivity

Stability: Stable under normal storage and use conditions.

Materials to Avoid (Incompatibility): Strong oxidizing agents, strong acids, strong bases (may react and affect coating performance).

Conditions to Avoid: Avoid high temperatures, open flames, strong oxidizers.

Hazardous Polymerization: Will not occur under normal conditions.

Hazardous Decomposition Products: Under extreme conditions (high temperatures), may decompose to produce carbon monoxide, carbon dioxide, etc.

11. Toxicological information

Acute Toxicity:

- Oral (Rat): LD50 > 2000 mg/kg (Tested per GB/T 21804-2008)

- Dermal (Rabbit): LD50 > 2000 mg/kg

- Inhalation (Rat, 4 h): LC50 > 5 mg/L

Irritation:

- Skin: Slightly irritating

- Eyes: Irritating

Mutagenicity: No mutagenicity data available.

Teratogenicity: No teratogenicity data available.

Carcinogenicity: No carcinogenicity data available.

12. Ecological information

Ecotoxicity: May be toxic to aquatic organisms (e.g., Fish LC50 ~100 mg/L- specify test species like Zebrafish, exposure duration like 96 h, and method).

Biodegradability: Some components are biodegradable.

Abiotic Degradation (Persistence): Some components degrade slowly in the environment.

Other Adverse Effects: May cause pollution if released into water bodies. Prevent material and waste from entering drains, waterways, or soil.

13. Disposal considerations

Waste Disposal Methods: Dispose of residual product and empty containers according to local, regional, national, and international hazardous waste regulations. Contact a licensed waste disposal company for recovery or treatment.

Disposal Precautions: Take precautions to prevent leakage during disposal to avoid environmental contamination.

14. Transport information

UN Number: Non-hazardous goods. Not assigned.

UN Proper Shipping Name: Non-hazardous goods

Transport Hazard Class(es): Non-hazardous goods

Packing Group: Non-hazardous goods. Not applicable.

Marine pollutant: No

Packing Method: Packed in sealed plastic pails/drums to prevent leakage.

Transport Precautions:

Ensure containers are sealed and secured during transport to prevent leakage, collapse, falling, or damage.

Avoid transport mixed with oxidizing agents, acids, or alkalis.

Transport vehicles should carry suitable types and quantities of firefighting equipment and spill response materials.

Transport during cooler hours (early morning/evening) in summer to avoid direct sunlight exposure.

15. Regulatory information

Applicable chemical regulatory frameworks (e.g., China "Regulations on the Safety Management of Hazardous Chemicals") and relevant Standards (e.g., GB 18582-2020 "Limit of harmful substances of architectural wall coatings", GB 36246-2018 "Synthetic materials surfaced athletic fields for primary and middle school", etc.). (Fill in according to actual applicability).

16. Other information

Date Prepared: Apr 28, 2026

Prepared By: Technical Department, Guangzhou Lianyi Chemical Co., Ltd.

Reviewed By: Lin Hongye

Revision History: First issue, Apr 28, 2026